General technical data

Weight
Approx. 17 kg
Dimensions
565 x 455 x 265 mm (case)
Operating temperature
5 to +45 °C
Product-/housing material
TPE/PC + ABS/PC + ABS + 10% GF
Connectable probes
1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x temperature probe; 1 x differential pressure
Product colour
Black
Standards
Germanischer Lloyd (DNV GL) Certificate Nippon Kaijik Kyokai (Class NK) certificate according to MARPOL Annex VI and NOx Technical Code 2008
Power supply
Li ion rechargeable battery; AC mains unit 100 V to 240 V (50 to 60 Hz)
Power consumption
max. 40 W
Pump flow
1 l / min. with flow monitoring
Max. pos. press./flue gas
50 mbar
Max. neg. press./flue gas
-300 mbar
Dewpoint calculation
0.04 °Ctd; 99 °Ctd
Interface
IR/IRDA interface; Bluetooth®; USB; data bus; trigger input; Differential Pressure; probe input/ probe inputs; DC-voltage input; Mains connection; dilution gas inlet for measurement range extension
Storage temperature
-20 to +50 °C

Temperature - TC Type K (NiCr-Ni)

Measuring range
-200 to +1370 °C
Accuracy
±0.4 °C (-100 to +200.0 °C)
±1.0 °C (-200 to -+1001.0 °C)
±1.0 °C (200 to +1370.0 °C)
Resolution
±0.1 °C (-200 to +1370.0 °C)

Absolute Pressure

Measuring range
600 to 1150 hPa
Accuracy
10.0
±10 hPa at -5 to 45 °C

Flue gas O₂

Measuring range
0 to 25 Vol.%
Accuracy
According to to MARPOL Annex VI and NOx Technical Code

Flue gas CO (with H₂-compensation)

Measuring range
0 to 3000 ppm
Accuracy
According to to MARPOL Annex VI and NOx Technical Code

Flue gas NO

Measuring range
0 to 3000 ppm
Accuracy
According to to MARPOL Annex VI and NOx Technical Code

Flue gas NO₂

Measuring range
0 to 500 ppm
Accuracy
According to to MARPOL Annex VI and NOx Technical Code

Flue gas SO₂

Measuring range
0 to 3000 ppm
Accuracy
According to to MARPOL Annex VI and NOx Technical Code

Flue gas CO₂ - NDIR

Measuring range
0 to 40 Vol.%
Accuracy
According to to MARPOL Annex VI and NOx Technical Code